Lumitester - PD 30

Lumitester - PD 30

ATP+AMP Rapid Hygiene Monitoring

Model: PD30

product Code.: 60486

More details

EA-52100-00

New

$1,439.25

Lumitester - PD 30    -    ATP+AMP Rapid Hygiene Monitoring

The lumitester PD-30 is an easy to use measuring instrument, with the help of which up to 2000 measurements can be taken and stored. The measurement data can be saved from Lumitester and at the end further processed on the measurement. The device is used for hygiene monitoring in pharmaceutical and medical spheres, catering, wholesale, etc.


The lumitester PD-30 used together with the LuciPac Pen, provides a rapid detection of food and microbiological residues on all product contact surfaces as effective testing of cleaning and disinfection measures. A quantitative determination of the intra- and extracellular adenosine triphosphate (ATP) and adenosine monophosphate (AMP) is performed in the portable lumitester PD-30. The system of the instrument measures not only the amount of the present ATP, but due to the reaction integrated AMP-system is also able to detect much more stable AMP. In such a way the sensitivity of the measurements taken by the lumitester is substantially increased, particularly in production areas, where highly processed foodstuffs are processed further. The lumitester for ATP and AMP is the most innovative device available. ATP and AMP are the molecules present in the cells of all living beings – no matter either it goes about animals, plants, mold, yeast or bacteria.

The measurements are conducted with especially for that purpose available ATP test tube LuciPac Pen. The surface is sampled with the swabs contained in the tube. Then the swab is pressed all the way down into the tube, until it comes into contact with the reaction liquid and the actual reagent. Due to the gentle shaking, the reaction liquid collects in the reaction chamber of the tube. The entire LuciPac Pen is then inserted into the measuring chamber of the lumitester PD-30. Then, the measurement is started. After 10 seconds, the measurement result in RLU (Relative Light Units) is shown on the display of the lumitester.

Features

- two measurement methods: ATP and AMP 
- HACCP implementation
- low weight 
- data transfer to the evaluation software
- data memory for 2000 measurement results
- low measuring time 
- automatic self-calibration 
- USB interface

Technical Specification

Detection method Analog integration via photodiodes
Data output RLU (Relative Light Unit)
Detection reagent special disposable product
Background disturbance max. 10 RLU
Measured width 0 ... 999999 RLU
Measuring time 10 seconds
Measuring Mode 1 ... 999
Temperature compensation +10 ... +40 ° C
Display LCD
Clock internally (date and time)
Interface USB
Number of individual data 2000
Self-diagnosis Autom. Cleanliness test before each use
Environmental conditions +5 ... +40 ° C, 20... 80 % RH
Storage conditions -10 ... +50 ° C, 20... 90 % RH
Language menu German
English 
French 
Spanish
Japanese 
Korean
Chinese (simple and traditional
Power supply 2 x AA battery
Dimensions 65 x 175 x 32 mm (W x H x D)
Weight approx. 235 g without batteries

You take samples with sterile LuciPac Pen, the detergents solution of the LuciPac Pen brings to the the release of ATP and AMP. By reacting with the substrate enzyme system (luciferin-luciferase) of the firefly, ATP and AMP release light in an enzymatic circulation reaction (patented AMP-ATP circulation technology) .The degree of luminescence is directly related to the present amount of ATP and AMP and can be quantified with the Lumitester PD-30 as Relative Light Units (RLU). The more bioluminescence is measured, the higher the degree of impurity is. The whole process takes less than 30 seconds. That means that without enrichment or incubation you know for sure after maximum half a minute how high the degree of contamination by organic residues, such as bacteria, is. The patented, genetically engineered enzyme of the firefly also has got such peculiarity as being detergents-tolerant. Thus, the rests of cleaning agents do not inhibit the reaction, the measurement and results are not distorted (Pat. No. EP 1041151 A1).
Especially simple and quick hygiene monitoring

Delivery Contents
1 x lumitester PD-30, 1 x cleaning brush, 1 x USB interface cable, 1 x hand strap, 2 x battery (AA), 1 x CD-ROM with software, 1 x use manual

No customer reviews for the moment.

Write a review

Write a review